JEFA Tech produces custom individual and bulk o...
JEFA Tech produces custom FAKRA cable assemblies! We support any and all FAKRA Code/Color and Gender. JEFA Tech uses the highest quality Amphenol brand FAKRA connectors in manufacturing of our cable...
JEFA Tech produces custom individual and bulk order FAKRA Cable Ass...
JEFA Tech produces custom FAKRA cable assemblies! We support any and all FAKRA Code/Color and Gender. JEFA Tech uses the highest quality Amphenol brand FAKRA connectors in manufacturing of our cable assemblies. FAKRA has its origin in automotive applications, but it...
Read MoreLow Loss 400 Installation Radius - Tightest Coi...
David asks "Due to foam core, what is the smallest coil diameter for LL400? Thanks" Answer: The tightest installation coil radius is 1", so roughly about a 3" diameter (measured...
Low Loss 400 Installation Radius - Tightest Coil Dia...
David asks "Due to foam core, what is the smallest coil diameter for LL400? Thanks" Answer: The tightest installation coil radius is 1", so roughly about a 3" diameter (measured...
Read MoreJEFA Tech 400 FLEX Center Conductor Measurement
Dale asks "Can you provide me with the Outer Diameter, in thousands (as near as possible) of JefaTech's Low Loss 400-Flex center conductor? The spec sheet says (0.036). I believe...
JEFA Tech 400 FLEX Center Conductor Measurement
Dale asks "Can you provide me with the Outer Diameter, in thousands (as near as possible) of JefaTech's Low Loss 400-Flex center conductor? The spec sheet says (0.036). I believe...
Read More400 vs 400 FLEX for UV Protection
Mike asks "I need to replace several runs of Times Microwave LMR-400UF. At the time I bought a 500-ft spool of it, they neglected to publish the fact that it...
400 vs 400 FLEX for UV Protection
Mike asks "I need to replace several runs of Times Microwave LMR-400UF. At the time I bought a 500-ft spool of it, they neglected to publish the fact that it...
Read MoreUniden SDS200 to OmniX base antenna cable recom...
Question from John: I have a base scanner Uniden SDS200 that I am looking at doing about 75' run to an OmniX base antenna to pick up mainly 800 Mhz...
Uniden SDS200 to OmniX base antenna cable recommenda...
Question from John: I have a base scanner Uniden SDS200 that I am looking at doing about 75' run to an OmniX base antenna to pick up mainly 800 Mhz...
Read MoreWhich cable is best for my ham radio shack? HF ...
Bruce asks:The situation:Â 1. HF: 35 feet to the hole in the wall of the house, then add 5 more to the radio.2. 2m/440: 41 feet to the hole in the...
Which cable is best for my ham radio shack? HF 2m/440
Bruce asks:The situation:Â 1. HF: 35 feet to the hole in the wall of the house, then add 5 more to the radio.2. 2m/440: 41 feet to the hole in the...
Read MoreWhich cable to choose for my 5G or 4G/LTE modem...
First is the cable type, we have 240F and 400F. The number refers to the diameter of the cable 0.240" and 0.400". The 240F is the smaller diameter of the...
Which cable to choose for my 5G or 4G/LTE modem/rout...
First is the cable type, we have 240F and 400F. The number refers to the diameter of the cable 0.240" and 0.400". The 240F is the smaller diameter of the...
Read MoreJEFA Tech LL400 cable has a Copper Clad Aluminu...
A copper clad aluminum center conductor is the standard in the industry for RG-8 size low loss cable such as JEFA Tech Low Loss 400. Â CCA is preferred due to...
JEFA Tech LL400 cable has a Copper Clad Aluminum cen...
A copper clad aluminum center conductor is the standard in the industry for RG-8 size low loss cable such as JEFA Tech Low Loss 400. Â CCA is preferred due to...